S H E N G S H I

Please Wait For Loading

FHBS standard curing room fully automatic temperature and humidity control equipment

FHBS standard curing room fully automatic temperature and humidity control equipment

FHBS standard curing room fully automatic temperature and humidity control equipment

1. Product Overview

The FHBS standard curing room fully automatic temperature and humidity control equipment is a specialized device used for standard curing of building materials samples such as concrete test blocks and cement specimens. It meets the requirements of GB/T 50081-2019 “Test Methods for Physical and Mechanical Properties of Concrete” and ISO standards for the curing environment (temperature 20 ± 1 ℃, humidity ≥ 95%). Through an intelligent control system, precise adjustment of temperature and humidity is achieved to ensure consistency in the curing conditions of the specimens.

2.  Core functions

  • Fully automatic control: using microcomputer PLC or touch screen control, automatically adjusting temperature and humidity without manual intervention.
  • Dual system regulation: dual-mode temperature control for cooling/heating: compressor cooling+electric heating tube heating, quickly stabilizing temperature.
  • Ultrasonic humidification: High frequency atomization humidification, with uniform humidity and no condensation of water droplets.
  • Data recording and alarm: It can store historical data and support sound and light alarms for abnormal situations (such as power outages and exceeding limits).
  • Energy saving design: equipped with a circulating air system and insulation layer to reduce energy consumption.

3.  Technical parameters

Project 

Parameters

Temperature control range: 0~50 ℃ (default setting: 20 ± 1 ℃)
Humidity control range  40%~99% RH (default ≥ 95%)
Temperature control accuracy  ± 0.5 ℃
Humidity control accuracy  ± 2% RH
Power supply voltage AC380V/220V (configured by model)
Power 3~10kW (depending on the area of the maintenance room)
Applicable space 10-50m ³ (customizable for larger capacity)
Brand Shengshiweiye

 

4. Operation process

  • Installation and debugging: The equipment is installed in the maintenance room, ensuring good sealing around and no leakage in the pipeline.
  • Power on settings: Set the target temperature (20 ℃) and humidity (95%), and start the automatic operation mode.
  • Daily monitoring: Observe real-time temperature and humidity through the display screen, and regularly check the water level in the water tank.
  • Placement of test pieces: interval between test pieces ≥ 10mm, avoid direct contact with spray nozzle.

5. Maintenance and Precautions

  • Regular maintenance:
    1. Clean the water tank and filter to prevent scale from clogging the humidifier.
    2. Check the sensitivity of the sensor and calibrate it if necessary (recommended every 6 months).
  • Fault handling:
    1. Insufficient humidity: Check if the humidifier is working and if the water source is sufficient.
    2. Large temperature fluctuations: Confirm the operating status of the compressor or heating tube, and check the sealing of the insulation layer.
    3. Safety reminder: The equipment should be grounded to prevent leakage and avoid direct operation of circuit parts in humid environments.

6.  Application scenarios

  • Construction Quality Inspection Center
  • Cement/concrete production enterprise laboratory
  • Materials laboratory of universities and research institutions

leave a comment