A1280 Mechanical Impurity Tester

A1280 Mechanical Impurity Tester

A1280 Mechanical Impurity Tester

August 28, 2026 Shenshi2018 0 Comments

Model A1280 Mechanical Impurity Tester is applicable for determining the content of mechanical impurities in various light‑weight and heavy‑weight oils, lubricating oils and additives of petroleum products. It is widely used in electric power, petroleum, chemical industry, commodity inspection and scientific research departments.

The instrument is widely used for quality inspection, production control and laboratory analysis in:

  • Petroleum refineries
  • Lubricant manufacturers
  • Chemical industries
  • Power plants
  • Scientific research institutes
  • Third-party testing laboratories

Mechanical impurities refer to insoluble solid contaminants such as:

  • Metal particles
  • Dust
  • Rust
  • Carbon residues
  • Foreign particles

These contaminants may affect lubrication performance, accelerate equipment wear and reduce oil service life.

The A1280 helps laboratories evaluate oil cleanliness and ensure petroleum products meet quality requirements.

Applicable Standard: GB/T 511

A1280 Mechanical Impurity Tester
A1280 Mechanical Impurity Tester

Technical Parameters

Item Specification
Water Bath Temperature Control RangeRoom Temp. ~ 90℃, adjustable
Water Bath Temperature DisplayLED digital display
Water Bath Temperature Control Accuracy±1℃
Funnel Temperature Control RangeRoom Temp. ~ 90℃, adjustable
Funnel Temperature DisplayLED 数字显示 (LED digital display)
Funnel Temperature Control Accuracy±2℃
Ambient Temperature5℃‑40℃
Relative Humidity<85%
Total Power Consumption≤1000W
Power SupplyAC220V±10%, 50Hz
Electric Furnace Heating Power1000W
Overall Dimensions370mm × 380mm × 600mm
Instrument Weight12.8kg
A1280 Mechanical Impurity Tester
A1280 Mechanical Impurity Tester

Product Features

  1. Digital display with intelligent temperature controller for temperature regulation.
  2. Nice appearance, easy‑to‑operate, stable and reliable performance.
  3. Achieves heating rate as required by the standard.
  4. The instrument mainly consists of glassware, constant‑temperature bath, electric furnace, vacuum pump and electronic temperature‑control box.

Working Principle

The A1280 adopts the filtration and gravimetric measurement method.

Testing procedure:

Step 1

The petroleum sample is heated and mixed with solvent.

Step 2

The sample passes through a standardized filter membrane.

Step 3

Mechanical impurities remain on the filter.

Step 4

After drying and weighing, the impurity content is calculated.

The result reflects the cleanliness level of the petroleum product.

Main Features

1. Dual Temperature Control System

The instrument provides independent temperature control for:

  • Water bath
  • Filtration funnel

Advantages:

✔ Stable heating condition
✔ Improved testing accuracy
✔ Better repeatability
✔ Meets laboratory testing requirements

The water bath temperature can be adjusted from room temperature to 90℃ with digital display and ±1℃ control accuracy.

2. Built-in Vacuum Filtration System

The A1280 integrates:

  • Vacuum pump
  • Filtration system
  • Temperature control unit

Benefits:

✔ Faster filtration process
✔ Stable vacuum operation
✔ Easy laboratory installation
✔ Reduced external equipment requirement

3. Digital Temperature Display

Equipped with LED digital temperature display:

  • Clear reading
  • Easy operation
  • Real-time monitoring

4. Professional Laboratory Structure

Designed for daily petroleum laboratory testing:

✔ Compact desktop design
✔ Simple operation
✔ Reliable performance
✔ Easy maintenance

Applications

Petroleum Refinery Testing

Used for:

  • Crude oil quality inspection
  • Fuel contamination analysis
  • Production quality control

Lubricating Oil Analysis

Applicable for:

  • Engine oil
  • Hydraulic oil
  • Turbine oil
  • Industrial lubricants

Power Industry

Used for:

  • Transformer oil inspection
  • Turbine oil monitoring
  • Equipment contamination analysis

Chemical Industry

Suitable for:

  • Additive testing
  • Hydrocarbon analysis
  • Research laboratories

FAQ

Q1: What is a Mechanical Impurity Tester used for?

A Mechanical Impurity Tester is used to measure insoluble solid contaminants in petroleum products, lubricating oils, heavy oils and additives.

Q2: What samples can A1280 test?

It can test:

  • Lubricating oil
  • Fuel oil
  • Heavy oil
  • Petroleum products
  • Oil additives

Q3: Which standard does A1280 follow?

The instrument follows GB/T511 mechanical impurity determination requirements.

Q4: Why is mechanical impurity testing necessary for lubricating oil?

Because solid contaminants can accelerate equipment wear and reduce lubrication performance.

Q5: Is A1280 suitable for petroleum laboratories?

Yes. It is widely used in petroleum, chemical, power and research laboratories.

Get a Bulk Quote / Inquiry:

If you are looking for a reliable supplier or need a custom wholesale price, contact our sales representative instantly via WhatsApp or Email.

leave a comment